Seismic Retrofitting Portland Oregon work in a crawl space

Earthquake bolting and bracing

Seismic Retrofitting Portland Oregon

Older house sitting loose on its foundation? Bolt and brace it so a strong quake doesn't shake it off.

✓Sill bolting ✓Cripple wall bracing ✓Prescriptive city plans

Older homes

Seismic Upgrades Portland: Bolting, Bracing and Straps

A seismic retrofit ties the wood frame of a house to its concrete foundation and stiffens the short walls in the crawl space, called cripple walls, so the house stays on its foundation when the ground shakes.

Age is the clearest clue. Homes built before 1974, when Oregon adopted its first statewide building code, are the ones most likely to be loose on their foundations. Portland foundation contractors see plenty of them.

Call (971) 512-4289

Is yours at risk?

Which Houses Need It Most

Look in the crawl space. If there are no bolts or plates fastening the wood sill to the concrete, or the cripple walls are covered only in siding or stucco on the outside, the house is a good candidate.

City guidance notes that weak cripple walls are the second most common structural weakness behind earthquake damage, and that homes bolted in the 1970s still failed where those walls weren't braced.

Call (971) 512-4289
Wood sill resting on a foundation with no bolts
A bare sill sitting on concrete with no bolts is the main thing to look for.

What gets installed

Earthquake Retrofit Portland: Step by Step

✓

Sill Bolting

Anchor bolts or steel plates fasten the wood sill to the concrete foundation every few feet.

✓

Cripple Wall Plywood

Structural plywood is nailed to the inside of the cripple walls to stop them racking over.

✓

Floor-to-Wall Connectors

Steel clips tie the floor framing to the top of the cripple wall.

✓

Water Heater Straps

Straps keep the water heater from tipping and breaking gas and water lines.

✓

Chimney Bracing

Unreinforced brick chimneys can be braced or lowered, often with engineering.

✓

Foundation Repairs

Crumbling concrete may need repair before bolts will hold.

Call (971) 512-4289

How it goes

From Crawl Space Check to Final Inspection

  1. Step01

    Crawl Space Survey

    The contractor checks access, sill condition, cripple wall height and the concrete.

  2. Step02

    Plan the Work

    Prescriptive city plans or an engineer's design, depending on the house.

  3. Step03

    Permit

    Seismic strengthening work usually goes through the city permit process.

  4. Step04

    Bolt and Brace

    Bolts, plates, plywood and connectors are installed under the house.

  5. Step05

    Inspection

    The work is inspected before it's covered or closed up.

Call (971) 512-4289
Plywood braced cripple wall with anchor bolts
Plywood on the cripple walls and bolts at the sill are the core of a retrofit.

City standards

Permits and Plans

Portland is the only jurisdiction in Oregon with its own prescriptive standards for earthquake retrofits of houses, which lets many one- and two-family homes be strengthened without a custom engineered design.

Those standards apply when the cripple walls are no more than 4 feet tall in one- and two-story houses. Taller walls, hillside foundations and unusual framing usually need an engineer.

Call (971) 512-4289

The big one

Why the Risk Is Real Here

Strong and sustained ground shaking is expected across the area in a Cascadia Subduction Zone earthquake, and smaller crustal faults run closer to the city. Houses sliding off their foundations is one of the most common types of damage in those quakes.

City guidance calls bolting and bracing the two most cost-effective steps for strengthening a house. For earthquake retrofitting, Portland, Oregon homeowners usually start there.

Call (971) 512-4289

Cost guide

How Much Does Bolting a House Cost?

A seismic retrofit with bolting and cripple wall bracing typically costs about $2,800 to $6,300.

Tall cripple walls, tight crawl spaces and foundation repairs add to the price. These are typical local ranges, not quotes.

Call (971) 512-4289

Earthquake prep

Questions About Bolting and Bracing

How do I know if my house is bolted?

Look along the wood sill in the crawl space or basement. Bolts with washers and nuts or steel plates every few feet mean it's anchored.

Does bolting and bracing need a permit?

Usually, yes. A Portland seismic retrofit goes through the city permit process, and many houses in Portland, OR can use the city's prescriptive plans.

What does a seismic retrofit cost?

A seismic retrofit with bolting and cripple wall bracing typically costs about $2,800 to $6,300.

Does a retrofit bring a house up to current code?

No. City guidance notes these measures reduce damage but don't bring a building up to current code.

Do houses with basements need bolting?

Often, yes. Basement houses can still need sill bolting, even without cripple walls.

House Not Bolted Down? Fix That First

Bolting and bracing an older house is one of the most cost-effective earthquake upgrades you can make.